Language Selection

Français

Molecular Detection by Real-Time RT-PCR

<<Return to Laboratory


Requisition Forms

Reference Details

Description:

Molecular detection of Hepatitis Delta virus by real-time RT-PCR.

Test Category:
Molecular Detection
Pathogen:
Hepatitis Delta virus (HDV)
Illnesses and Diseases:
  • Hepatitis D
Specimen:

Serum or plasma sample. Minimum volume required for serum or plasma – 1.0 mL.

Collection Method:

Collect blood in serum separator tubes (SST) or EDTA tubes.

Specimen Processing, Storage and Shipping:

Store samples frozen until shipped for testing. Ship frozen on dry ice.

Transportation of Dangerous Goods:

Shipping of specimens shall be done by a TDG certified individual in accordance with TDG regulations. For additional information regarding classification of specimens for the purposes of shipping, consult either Part 2 Appendix 3 of the TDG Regulations or section 3.6.2 of the IATA Dangerous Goods Regulations as applicable.

 

Patient Criteria:

Suspected Hepatitis Delta virus infection. Serology results must show markers to the Hepatitis D virus.

Accompanying Documentation:

Completed Viral Hepatitis and Bloodborne Pathogens requisition including sender name, address and telephone number.  Patient name or identifier (referring specimen lab #), date of birth, suspected exposure, test(s) requested.  Type of specimen and date collected.  If possible, include the clinical history and lab results that have already been done at local or provincial laboratories.

Comments:

Only samples that are positive for anti-HDV antibodies will be tested. Samples submitted for anti-HDV serology testing are automatically reflexed to HDV RNA testing, if positive for antibodies. Anti-HDV negative specimens are not automatically tested for HDV RNA. RNA testing may be requested with justification (immunosuppression, treatment monitoring etc.).

Methods and Interpretation of Results:

Detection of HDV RNA using in-house real-time quantitative RT-PCR. HDV viral load quantification will be reported on all molecular detection requests.

Turnaround Time:

19 calendar days. Positive anti-HDV samples that are reflexed to HDV RNA testing have an extended turnaround time of 21 calendar days

Contact:
Phone #: (204) 789-6512
Fax: (204) 318-2222
References:
  1. Theamboonlers A, Hansurabhanon T, Verachai V, Chongsrisawat V, Poovorawan Y. Hepatitis D virus infection in Thailand: HDV genotyping by RT-PCR, RFLP and direct sequencing. Infection. 2002;30:140-4.
  2. Osiowy C, Day J, Lee E. (2024) Laboratory development of an RNA quantitative RT-PCR assay reporting in international units for hepatitis D virus. Frontiers in Microbiology,15, Article 1472826. https://doi.org/10.3389/fmicb.2024.1472826
Related Information: